Page 115 - Revista Portuguesa - SPORL - Vol 60. Nº3
P. 115

convenient tool, especially in emergency          2015;2015:746560. doi: 10.1155/2015/746560.
          settings,  and  relevant  complications  remain   3. Hensel M, Güldenpfennig T, Schmidt A, Krumm
                                                            M. Continuous cuff pressure measurement during
          rare. This  singular  case illustrates the        laryngeal  mask  anaesthesia:  an  obligatory  measure  to
          first  published  case  of  bilateral  arytenoid   avoid  postoperative complications.  Anaesthesist.  2016
          dislocation  after  LMA  and  was  treated  with   May;65(5):346-52. doi: 10.1007/s00101-016-0160-9
          voice therapy. It is important to properly        4.  Shin  HW,  Yoo  HN2,  Bae  GE,  Chang  JC,  Park  M2,  You
                                                            HS.  et  al.  Comparison  of  oropharyngeal  leak  pressure
          follow-up patients after LMA, so we don't miss    and clinical performance of LMA ProSeal™ and i-gel® in
          rare but potentially treatable complications.     adults: Meta-analysis and systematic review. J Int Med
                                                            Res. 2016 Jun;44(3):405-18. doi: 10.1177/0300060515607386.
                                                            5. Sataloff RT, Bough ID, Spiegel JR. Arytenoid dislocation:
          Agradecimentos                                    diagnosis and treatment. Laryngoscope. 1994 Nov;104(11
          Sem agradecimentos.                               Pt 1):1353-61. doi: 10.1288/00005537-199411000-00007.
                                                            6. Rosenberg MK, Rontal E, Rontal M, Lebenbom-Mansour
          Conflito de Interesses                            M. Arytenoid cartilage dislocation caused by a laryngeal
                                                            mask  airway  treated  with  chemical  splinting.  Anesth
          Os autores declaram que não têm qualquer          Analg. 1996 Dec;83(6):1335-6. doi: 10.1097/00000539-
          conflito de interesse relativo a este artigo.     199612000-00037.
                                                            7. Cros AM, Pitti  R, Conil  C, Giraud D, Verhulst  J.
          Confidencialidade dos dados                       Severe  dysphonia  after  use  of  a  laryngeal  mask
                                                            airway. Anesthesiology. 1997 Feb;86(2):498-500. doi:
          Os  autores  declaram  que  seguiram  os          10.1097/00000542-199702000-00027.
          protocolos do seu trabalho na publicação dos      8.  Close  LG,  Merkel  M,  Watson  B,  Schaefer  SD.
          dados de pacientes.                               Cricoarytenoid subluxation, computed tomography, and
                                                            electromyography  findings.  Head  Neck  Surg.  Jul-Aug
                                                            1987;9(6):341-8. doi: 10.1002/hed.2890090607.
          Proteção de pessoas e animais                     9. Maue WM, Dickson DR. Cartilages and ligaments of the
          Os  autores  declaram  que  os  procedimentos     adult human larynx. Arch Otolaryngol. 1971 Nov;94(5):432-
          seguidos estão de acordo com os regulamentos      9. doi: 10.1001/archotol.1971.00770070678008.
                                                            10. Lee DH, Yoon TM, Lee JK, Lim SC. Treatment outcomes of
          estabelecidos  pelos  diretores  da  Comissão     closed reduction of arytenoid dislocation. Acta Otolaryngol.
          para  Investigação  Clínica  e  Ética  e  de  acordo   2013 May;133(5):518-22. doi: 10.3109/00016489.2012.758387.
          com a Declaração de Helsínquia da Associação      11. Lou Z, Lin Z. The appropriate time for closed reduction
          Médica Mundial.                                   using local anesthesia in arytenoid dislocation caused
                                                            by intubation: a clinical research. Acta Otolaryngol. 2017
                                                            Mar;137(3):331-336. doi: 10.1080/00016489.2016.1230276.
          Política   de   privacidade,   consentimento
          informado e Autorização do Comité de Ética
          Os autores declaram que têm o consentimento
          para o uso de fotografias e vídeos dos pacientes
          neste artigo.


          Financiamento
          Este trabalho não recebeu qualquer contribuição,
          financiamento ou bolsa de estudos.

          Disponibilidade dos Dados científicos
          Não  existem  conjuntos  de  dados  disponíveis
          publicamente relacionados com este trabalho.


          Referências bibliográficas
          1. Pollack CV. The laryngeal mask airway: a comprehensive
          review for the Emergency Physician. J Emerg Med. 2001
          Jan;20(1):53-66. doi: 10.1016/s0736-4679(00)00273-0.
          2.  Michalek  P,  Donaldson  W,  Vobrubova  E,  Hakl  M.
          Complications associated with the use of supraglottic
          airway devices in perioperative medicine. Biomed Res Int.


                                                                                  Volume 60 . Nº3 . Setembro 2022 271
   110   111   112   113   114   115   116   117   118   119   120