Page 15 - Revista Portuguesa - SPORL - Vol 48 Nº4
P. 15

TABELA 1                                          GRÁFICO 1
          Valores médios dos limiares tonais em campo livre com implante.  Gráfico com os valores tonais médios com implante em campo livre

                          Group Statistics a
                   Phone  N   Mean      Std.   Std. Error
                                      Deviation  Mean
          CL250D   Sim    47    32,66     9,883   1,442
                   Não    23    35,87     9,493   1,979
          CL500D   Sim    47    30,32     7,547   1,101
                   Não    23    33,70     8,819   1,839
          CL1000D  Sim    47    30,64     5,674   0,828
                   Não    23    34,78     7,148   1,490
          CL2000D  Sim    47    30,74     6,674   0,974
                   Não    23    31,74     8,063   1,681                                                            ARTIGO ORIGINAL ORIGINAL ARTICLE
          CL4000D  Sim    47    36,06     7,867   1,147
                   Não    23    39,95    15,905   3,316
          CL6000D  Sim    47    36,06    10,832   1,580
                   Não    23    42,61    14,528   3,029
          a . Teste com telefone = Sim

          TABELA 2
          Teste t para amostras independentes comparando os limiares
          tonais em campo livre entre os dois grupos.
                                                Independent Samples test a
                                  Levene’s Test for                t-test for Equality of Means
                                 Equality of Variances
                                                                                             95% Confidence
                                   F       Sig.     t      df     Sig.    Mean     Std. Error   Interval of the
                                                                (2-tailed) Difference  Difference  Difference
                                                                                             Lower  Upper
          CL250D   Equal variances   0,120  0,730  -1,293    68    0,200     -3,21     2,483  -8,165  1,745
                   assumed
                   Equal variances                -1,311  45,414   0,196     -3,21     2,449  -8,141  1,721
                   not assumed
          CL500D   Equal variances   2,638  0,109  -1,663    68    0,101     -3,38     2,031  -7,429  1,676
                   assumed
                   Equal variances                -1,575  38,248   0,123     -3,38     2,143  -7,714  1,961
                   not assumed
          CL1000D  Equal variances   1,122  0,293  -2,631    68    0,011     -4,14     1,575  -7,287  -1,002
                   assumed
                   Equal variances                -2,431  36,022   0,020     -4,14     1,705  -7,602  -0,687
                   not assumed
          CL2000D  Equal variances   0,688  0,198  -0,546    68    0,587     -0,99     1,820  -4,627  2,638
                   assumed
                   Equal variances                -0,512  37,222   0,612     -0,99     1,943  -4,930  2,941
                   not assumed
          CL4000D  Equal variances   2,893  0,094  -1,160    68    0,250     -3,28     2,830  -8,932  2,364
                   assumed
                   Equal variances                -0,936  27,395   0,358     -3,28     3,509  -10,480  3,912
                   not assumed
          CL6000D  Equal variances   0,085  0,771  -2,117    68    0,038     -6,54     3,092  -12,715  -0,375
                   assumed
                   Equal variances                -1,916  34,380   0,064     -6,54     3,417  -13,485  0,396
                   not assumed
          a . Teste com telefone = Sim



                                                                                     VOL 48 . Nº4 . DEZEMBRO 2010     185